Malaysia-Cambodia-Thailand (MCT) Cable: latency up to 2.3× normal, 2 Aug 2026
What we measured
| Cable | Malaysia-Cambodia-Thailand (MCT) Cable |
| Segment | Rayong, TH → Cherating, MY |
| Detected | 2026-08-02 23:32 UTC |
| Resolved | 2026-08-03 02:00 UTC |
| Duration | 2h 28m |
| Observed latency | 34.9 ms |
| Baseline | 50.7 ms · 2.3× |
| Increase | +130% |
| Severity | warning |
Who is affected
Countries where Malaysia-Cambodia-Thailand (MCT) Cable comes ashore, how much of their submarine diversity this cable represents, and what our measurements into them show.
| Country | Dependence on this cable | Other submarine cables | What the measurements show |
|---|---|---|---|
| Cambodia resilience index: 37 · vulnerable |
1 of 3 cables (33% of submarine diversity) | Asia Africa Europe-1 (AAE-1), Sihanoukville-Hong Kong (SHV-HK) | median 238 ms today vs 216 ms over 30 days (142 routes) - unchanged |
| Malaysia resilience index: 100 · resilient |
1 of 34 cables (3% of submarine diversity) | APCN-2, Asia Africa Europe-1 (AAE-1), Asia Link Cable (ALC) +30 more | median 194 ms today vs 182 ms over 30 days (304 routes) - unchanged |
| Thailand resilience index: 100 · resilient |
1 of 18 cables (6% of submarine diversity) | Asia Africa Europe-1 (AAE-1), Asia Direct Cable (ADC), Asia Pacific Gateway (APG) +14 more | median 168 ms today vs 221 ms over 30 days (391 routes) - faster |
Dependence is structural (share of the country's submarine cables), not a traffic share: real traffic distribution across cables is not public.
Vessels nearby at the time of the incident
Vessel data for this period is not available.
Alert check
Not confirmed. We asked other measurement points, and they did not see the trouble. The alert stays on record but is not counted as an incident. what this means
Path analysis
Traffic kept the same route. Latency rose without a visible path change, which points at congestion or a fault on the existing route rather than a reroute.
Cross-probe verdict. Other measurements did not confirm the event, so we do not count it as a cable fault.
Timeline
- Alert 2026080201: warning - ratio 2.3x
- Alert #164 improving: 2/3 consecutive OK
- Alert #164 resolved: RTT 34.92ms (baseline 50.69ms), 3 consecutive OK
Detection method
Latency is sampled continuously from our probe network. An alert opens when round-trip time to a monitored endpoint holds above its rolling baseline, and closes automatically once it returns. Full method is described on the methodology page.