Magnitude 5.3 Earthquake Near Taiwan Causes Latency Spike on EAC-C2C Cable
Earthquake off the Coast of Taiwan
On November 25, 2026, at 10:47 local time, an earthquake of magnitude 5.3 occurred. The epicenter was located 83 km east-southeast of Hanchun, Taiwan. This event affected an area with high submarine cable density, necessitating monitoring of potential impacts on data transmission.
Cables in the Earthquake Zone
Within a 500 km radius of the epicenter, there are eight submarine cables:
- EAC-C2C (36,500 km, RFS 2002, Telstra) - node in Fangshan, Taiwan (101.1 km from the epicenter).
- Asia United Gateway East (AUG East) (8,900 km, RFS 2029, Amazon Web Services, Arteria) - node in Dawu, Taiwan (87.6 km).
- Southeast Asia-Japan Cable 2 (SJC2) (10,500 km, RFS 2025, China Mobile, Chunghwa Telecom) - node in Fangshan, Taiwan (101.1 km).
- Taiwan Penghu Kinmen Matsu No.2 (TPKM2) (467 km, RFS 2000, Chunghwa Telecom) - node in Budai, Taiwan (221.1 km).
- Taiwan Penghu Kinmen Matsu No.3 (TPKM3) (510 km, RFS 2013, Chunghwa Telecom) - node in Huxi Township, Taiwan (273.7 km).
- Okinawa Remote Islands (915 km, RFS 2017, Okinawa Prefecture) - node in Hateruma, Japan (339.9 km).
- Topaz (RFS 2023, Google) - node in Toucheng, Taiwan (340 km).
- Pacific Light Cable Network (PLCN) (11,806 km, RFS 2022, Google, Meta) - node in Toucheng, Taiwan (340 km).
Measurements: Impact on EAC-C2C
According to our monitoring, the EAC-C2C cable has shown a significant increase in latency. The average RTT value increased from 100.9 ms to 186.9 ms, which is an increase of 86.0 ms. This deviation exceeds 2.1 standard deviations from the baseline level, indicating temporary transmission difficulties. Other cables in the zone, including AUG East and SJC2, have held up under the load and continue to function normally.
Potential consequences
A sharp increase in latency on EAC-C2C may affect data transmission routes between Asia and other regions, as this cable is part of a large network connecting East and Southeast Asia. In case of further complications, traffic may be redirected through alternative routes such as SJC2 or AUG East, which could potentially increase their load.
The stable operation of other cables in the zone underscores the importance of load distribution across multiple routes to ensure the reliability of the global network.
Plans for further monitoring
We will continue to monitor delays on all cables in the earthquake zone, paying special attention to EAC-C2C. Special attention will also be given to the condition of SJC2 and AUG East cables, which may take on additional traffic in case of worsening conditions. In the event of further anomalies, we will update the information promptly.