High-capacity Undersea Guernsey Optical-fibre (HUGO) cable: latency up to 2.4× normal, 5 Aug 2026
What we measured
| Cable | High-capacity Undersea Guernsey Optical-fibre (HUGO) |
| Segment | Porthcurno, GB → Saints Bay, GG |
| Detected | 2026-08-05 21:02 UTC |
| Resolved | 2026-08-05 22:32 UTC |
| Duration | 1h 30m |
| Observed latency | 29.8 ms |
| Baseline | 48.3 ms · 2.41× |
| Increase | +141% |
| Severity | warning |
Who is affected
Countries where High-capacity Undersea Guernsey Optical-fibre (HUGO) comes ashore, how much of their submarine diversity this cable represents, and what our measurements into them show.
| Country | Dependence on this cable | Other submarine cables | What the measurements show |
|---|---|---|---|
| France resilience index: 100 · resilient |
1 of 35 cables (3% of submarine diversity) | 2Africa, Africa Coast to Europe (ACE), Africa-1 +31 more | median 67 ms today vs 76 ms over 30 days (3896 routes) - unchanged |
| Guernsey resilience index: 53 · vulnerable |
1 of 5 cables (20% of submarine diversity) | Channel Islands-9 Liberty Submarine Cable, Guernsey-Jersey-4, INGRID +1 more | median 71 ms today vs 69 ms over 30 days (50 routes) - unchanged |
| United Kingdom resilience index: 100 · resilient |
1 of 68 cables (1% of submarine diversity) | 2Africa, Amitie, Apollo +64 more | median 62 ms today vs 79 ms over 30 days (3433 routes) - faster |
Dependence is structural (share of the country's submarine cables), not a traffic share: real traffic distribution across cables is not public.
Vessels nearby at the time of the incident
Vessel data for this period is not available.
Alert check
Not confirmed. We asked other measurement points, and they did not see the trouble. The alert stays on record but is not counted as an incident. what this means
Path analysis
Traffic kept the same route. Latency rose without a visible path change, which points at congestion or a fault on the existing route rather than a reroute.
Cross-probe verdict. Other measurements did not confirm the event, so we do not count it as a cable fault.
Timeline
- Alert 2026080502: warning - ratio 2.41x
- Alert #166 improving: 1/3 consecutive OK
- Alert #166 resolved: RTT 29.83ms (baseline 48.31ms), 3 consecutive OK
Detection method
Latency is sampled continuously from our probe network. An alert opens when round-trip time to a monitored endpoint holds above its rolling baseline, and closes automatically once it returns. Full method is described on the methodology page.