Havhingsten/CeltixConnect-2 (CC-2): 1.9× baseline latency
What we measured
| Cable | Havhingsten/CeltixConnect-2 (CC-2) |
| Segment | Blackpool, GB → LoughShinny, IE |
| Detected | 2026-05-29 02:32 UTC |
| Resolved | 2026-05-29 04:01 UTC |
| Duration | 1h 29m |
| Observed latency | 76.7 ms |
| Baseline | 40.3 ms · 1.9× |
| Increase | +113% |
| Severity | warning |
Path analysis
Traffic kept the same route. Latency rose without a visible path change, which points at congestion or a fault on the existing route rather than a reroute.
Cross-probe verdict. Only one probe saw it. We treat this as a probable false positive and label it as such.
Timeline
- Alert 2026052901: warning — ratio 2.13x
- Alert #129 improving: 1/3 consecutive OK
- Alert #129 resolved: RTT 76.67ms (baseline 40.32ms), 3 consecutive OK
Detection method
Latency is sampled continuously from our probe network. An alert opens when round-trip time to a monitored endpoint holds above its rolling baseline, and closes automatically once it returns. Full method is described on the methodology page.