Tannat: 0.13× baseline latency
What we measured
| Cable | Tannat |
| Segment | Las Toninas, AR → Santos, BR |
| Detected | 2026-04-30 13:01 UTC |
| Resolved | 2026-04-30 15:01 UTC |
| Duration | 2h 0m |
| Observed latency | 27.3 ms |
| Baseline | 207.5 ms · 0.13× |
| Increase | +204% |
| Severity | warning |
Path analysis
Traffic kept the same route. Latency rose without a visible path change, which points at congestion or a fault on the existing route rather than a reroute.
Cross-probe verdict. Only one probe saw it. We treat this as a probable false positive and label it as such.
Timeline
- Alert 2026043001: warning — ratio 3.04x
- Alert #99 improving: 1/3 consecutive OK
- Alert #99 improving: 2/3 consecutive OK
- Alert #99 resolved: RTT 27.26ms (baseline 207.47ms), 3 consecutive OK
Detection method
Latency is sampled continuously from our probe network. An alert opens when round-trip time to a monitored endpoint holds above its rolling baseline, and closes automatically once it returns. Full method is described on the methodology page.